Thermal network design features enable the planning and analysis of district heating and cooling systems. The process is divided into three parts:

  1. Part 1 — Layout: generate or load a pipe trench layout and select which buildings are connected per service.
  2. Part 2 — Flow & Sizing: simulate thermal-hydraulic performance and size pipes for a single network.
  3. Part 2b — Multi-Phase: optimise pipe sizing across a sequence of networks that represent phased expansion or decommissioning over time.

CEA 4 supports multiple network layouts per scenario, lets you chain a new layout off an existing one (to add or remove buildings), and now lets you decommission buildings between phases under a sunk-infrastructure cost model.


Thermal Network Part 1: Layout

Overview

Generates a thermal network pipe trench (a single geometry that can carry both DH and DC pipes) and the service-specific node sets for district heating (DH) and/or district cooling (DC). There are three ways to produce a layout:

  1. Auto-generate from street geometry using a Steiner spanning tree over the requested buildings.
  2. Upload your own shapefile / GeoJSON network.
  3. Chain off an existing CEA-generated network (existing-network parameter) and adjust its connected buildings — adding new ones, removing decommissioned ones, or both — without redrawing the trench from scratch.

The same tool handles all three paths; which one runs depends on which parameters you set.

New in CEA 4:

  • Multiple network layouts per scenario with unique names (e.g. sub1, sub2, baseline, optimised).
  • Universal pipe trench (layout.shp) shared by DH and DC, with separate per-service node files.
  • existing-network + network-layout-mode lets you evolve a network across phases while keeping pipe names stable so downstream tools can match pipes across runs.
  • Plant nodes are protected infrastructure: when filtering a network, plant nodes and their incident pipes are never pruned, even if the anchor building was removed.

When to Use

  • Designing a new district heating or cooling network
  • Evolving an existing network across phases (adding new consumers, decommissioning old ones)
  • Comparing alternative network designs side-by-side
  • Loading a network designed externally in Rhino/Grasshopper/QGIS

How It Works

Auto-generation path:

  1. Read building footprints and street network
  2. Pick the set of connected buildings (from heating-/cooling-connected-buildings config or from supply.csv)
  3. Run a Kou or Mehlhorn Steiner spanning tree over those buildings along the street graph
  4. Add plant nodes near the anchor building (highest demand or user-specified)
  5. Write layout.shp (universal trench), DH/layout/nodes.shp, DC/layout/nodes.shp

Existing-network path:

  1. Load the existing network’s layout.shp + node files, merging DC and DH nodes into a single working graph
  2. Apply the selected network-layout-mode to reconcile connected buildings with the heating-/cooling-connected-buildings parameters
  3. Write the reconciled output under the new network name. Original pipe names are preserved for shared geometries so multi-phase tools (Part 2b) can match pipes across phases.

Prerequisites

  • Energy Demand Part 2 — building loads must be available
  • Streets Helper — street network must exist (only needed for auto-generation or for augment/filter modes that add new pipes)
  • Zone geometry

Required Input Files

  • Street network: streets.shp
  • Total demand: Total_demand.csv
  • Zone geometry: building footprints
  • For existing-network: the prior network’s layout.shp + {DH,DC}/layout/nodes.shp under outputs/data/thermal-network/{existing_name}/

Key Parameters

ParameterDescriptionTypical Value
network-nameUnique name for the layout being createde.g. sub1, baseline, optimised
network-typeServices to generate: DH, DC, or both['DH'], ['DC'], ['DH', 'DC']
existing-networkName of a prior network to chain off. Leave blank for a fresh auto-generation.blank, or sub1
network-layout-modeHow to reconcile connected buildings when loading an existing network or a user-provided one. See below.validate / augment / filter
auto-modify-networkWhether augment / filter modes may actually modify the network. If false, they error instead of modifying.true
heating-connected-buildingsDH consumers (overrides supply.csv when overwrite-supply-settings=true)e.g. ['B1001','B1002',...]
cooling-connected-buildingsDC consumerse.g. ['B1001','B1003']
consider-only-buildings-with-demandDrop buildings with zero heating/cooling demandtrue
connection-candidatesHow many candidate trunk connection points per building (Kou only)3
snap-toleranceMax distance to snap near-miss endpoints (m)0.5
edges-shp-path / nodes-shp-pathPaths to a user-provided shapefile layoutblank for auto
network-geojson-pathPath to a user-provided GeoJSON layoutblank

Network Layout Modes

When loading an existing network or a user-provided layout, the engine reconciles the loaded buildings against heating-/cooling-connected-buildings according to network-layout-mode:

ModeMissing buildingsExtra buildingsUse case
validate❌ Error❌ ErrorStrict check — fail if the loaded network doesn’t match the parameter exactly
augment➕ Add (Steiner tree off the street network)✓ KeepGrow an existing network — add new connections, keep everything that was there
filter➕ Add➖ Remove (with plant preservation and stub pruning)Shrink or refine an existing network — drop decommissioned buildings, keep the rest

Plant preservation invariant for filter: plant nodes and the pipes connecting them to the trunk are never pruned, even if the building they were anchored to was removed. If a plant ends up in a component with no surviving consumers, the plant and its pipework are still kept and a warning is printed.

Stub pruning: after filter drops a building, any junction node with degree ≤ 1 that isn’t a terminal or plant is iteratively removed along with its pipe, so the output doesn’t contain dangling pipe stubs.

How to Use

  1. Complete prerequisites: Energy Demand + Streets Helper.

  2. Pick the flow — one of:

    • Fresh auto-generation: leave existing-network, edges-shp-path, nodes-shp-path, network-geojson-path all blank.
    • User-provided layout: set edges-shp-path + nodes-shp-path (or network-geojson-path).
    • Chain off an existing network: set existing-network to the previous network’s name.
  3. Run layout generation:

    • Navigate to Thermal Network Design → Part 1: Layout
    • Give the new layout a unique network-name
    • Select network-type (DH, DC, or both)
    • If chaining or uploading, pick a network-layout-mode
    • Set heating-connected-buildings / cooling-connected-buildings if you want to override supply.csv
    • Click Run
  4. Processing time: usually under a minute for typical districts.

Output Files

All outputs go under outputs/data/thermal-network/{network_name}/:

  • layout.shpuniversal pipe trench (DC + DH edges deduplicated by geometry). This is the authoritative edge file.
  • DH/layout/nodes.shp — DH-service nodes (consumers, plants, junctions)
  • DH/layout/edges.shp — DH-service edges written by Part 2 downstream
  • DC/layout/nodes.shp — DC-service nodes
  • DC/layout/edges.shp — DC-service edges (Part 2)
  • connectivity.json — per-building service metadata (which buildings connect to which service, with overwrite_supply_settings flag and timestamp)

Edge-name stability: when using existing-network, Part 1 preserves the original pipe names for any edge that existed in the source layout. Only genuine name collisions are renumbered. This is what makes multi-phase matching work — sub1’s PIPE1 stays PIPE1 when you derive sub2 from sub1.

Understanding Layout Results

Key metrics to review:

  • Total pipe length (m or km)
  • Number of connected buildings
  • Network density (pipe length per connected building)
  • Building connection points

Typical network characteristics:

  • Tree networks: Pipe length = 0.8-1.5× linear distance between buildings
  • Looped networks: Pipe length = 1.2-2.0× tree network length
  • Urban density: 20-80 m pipe per building

Visualising the Network

  1. Use CEA-4 App 3D viewer to see network overlay
  2. Export to Rhino/Grasshopper for detailed visualisation
  3. Open shapefiles in QGIS or ArcGIS

Tips

  • Accurate streets matter: network follows streets, so street quality affects results
  • Check connectivity: verify all desired buildings are connected to a plant
  • Consider future expansion: leave capacity for additional connections
  • Manual editing: you can manually edit the generated shapefiles if needed
  • Multiple scenarios: create several network layouts (e.g. baseline, low-temp, high-density) to compare different design approaches
  • Network naming: use descriptive names that help you remember the design strategy (e.g. tree-80C, loop-60C, sub1, sub2)
  • Chaining via existing-network: for phased scenarios, derive each phase from the previous one using existing-network + filter or augment. This preserves pipe names across phases so Part 2b can match pipes correctly.
  • filter vs augment: pick filter when the new phase should be an exact match to the listed connected buildings (drops decommissioned buildings, adds new ones). Pick augment when you only want to add buildings to an existing layout without removing anything.
  • Plant preservation: when a filter run removes a building that was anchoring a plant, the plant node and its pipe stay put. You’ll see a warning in the log if a plant ends up with no surviving consumers.

Troubleshooting

Issue: Not all buildings connected

  • Check that the street network covers the building areas
  • Some buildings may be too far from streets — Part 1 snaps via snap-tolerance, but distances beyond that won’t be bridged

Issue: Network layout doesn’t follow streets well

  • Improve street network quality with Streets Helper
  • Manually add missing street segments

Issue: Missing output shapefiles

  • Check for error messages in the log
  • Verify Total_demand.csv exists and has valid data for every connected building

Issue: Validation failed for DH (cooling)/... when using existing-network

  • The existing network’s building set doesn’t match heating-/cooling-connected-buildings
  • Fix: switch network-layout-mode from validate to augment (to add missing buildings) or filter (to also remove extras), and make sure auto-modify-network=true

Issue: “Duplicated NODE IDs” when Part 2 reads the layout

  • Usually caused by name collisions in the merged universal trench
  • Fix: re-run Part 1 — the current version auto-resolves name collisions via _resolve_duplicate_pipe_names and merges DC + DH nodes with canonical ids to prevent this

Thermal Network Part 2: Flow & Sizing

Overview

Performs detailed thermal hydraulic simulation of the network created in Part 1. This feature calculates mass flow rates, pipe sizes, temperatures, pressure drops, and pump requirements for district heating or cooling systems.

When to Use

  • After generating network layout (Part 1)
  • Sizing pipes for district energy systems
  • Calculating pumping energy and pressure requirements
  • Assessing thermal losses in distribution
  • Verifying network hydraulic feasibility

What It Calculates

Hydraulic Analysis:

  • Mass flow rates in each pipe segment (kg/s)
  • Required pipe diameters (mm)
  • Pressure drops along network (Pa)
  • Pump head and power requirements (kW)

Thermal Analysis:

  • Supply and return temperatures at each node (°C)
  • Heat losses from pipes (kW, kWh/year)
  • Temperature drops along network
  • Building substation heat exchangers

Network Performance:

  • Total annual heat delivered (MWh/year)
  • Total annual heat losses (MWh/year, %)
  • Pumping energy consumption (MWh/year)
  • Peak loads and flows (kW, kg/s)

Prerequisites

  • Thermal Network Part 1 - Network layout must exist
  • Energy Demand Part 2 - Building hourly demands needed
  • Weather file for ground temperature

Required Input Files

  • Network layout: Nodes and edges shapefiles (from Part 1)
  • Building demands: Individual building demand files (BXXX.csv)
  • Component databases: Pipe and system properties
  • Weather file: For ground temperature calculation

Key Parameters

ParameterDescriptionTypical Value
Network nameSelect which network layout to simulateChoose from dropdown (created in Part 1)
Network typeDH or DCMust match the network created in Part 1
Supply temperatureNetwork supply temp80°C (DH) / 6°C (DC)
Return temperatureNetwork return temp50°C (DH) / 12°C (DC)
Pipe insulationInsulation standardStandard / High performance
Ground temperatureFor heat loss calculationFrom weather file
MultiprocessingParallel processingEnabled

Note on temperature: The network temperature regime is fully determined in Part 2 by the supply/return temperature parameters. The order of heating/cooling services configured in Part 1 does not affect the temperature regime.

How to Use

  1. Complete network layout (Part 1)

  2. Configure parameters:

    • Navigate to Thermal Network Design
    • Select Thermal Network Part 2: Flow & Sizing
    • Select network name from dropdown (must be created in Part 1)
    • Select network type (must match the type used in Part 1)
    • Set supply/return temperatures:
      • District heating: 70-90°C supply, 40-50°C return
      • Low-temperature district heating: 50-70°C supply, 30-40°C return
      • District cooling: 5-8°C supply, 12-15°C return
    • Choose pipe insulation standard
    • Enable multiprocessing
  3. Run analysis:

    • Click Run
    • Processing time: 10-60 minutes depending on network size and complexity

Output Files

All Part 2 outputs are written under outputs/data/thermal-network/{network_name}/{DH|DC}/:

  • Edge sizing results (edges.csv / edge_list.csv): pipe diameters, mass flow rates, pressure drops, heat losses per metre, temperature drops
  • Node results (nodes.csv): node pressures, supply/return temperatures, building heat exchanger sizing
  • Plant thermal requirement (plant_thermal_load_kW.csv): hourly heat duty at each plant
  • Plant pumping requirement (plant_pumping_load_kW.csv): hourly pumping power
  • Network summary: total pipe length and volume, annual heat losses, pumping energy
  • Substation files: one CSV per connected building

Note: Results are organised by network name, so you can compare performance across different network designs without overwriting each other.

Pipe Cost Database

Part 2 and Part 2b both read pipe costs from {scenario}/inputs/technology/COMPONENTS/DISTRIBUTION/THERMAL_GRID.csv. The following columns are required — any missing column will cause Part 2b (multi-phase sizing) to error out with a clear message pointing at the file:

ColumnMeaningExample
pipe_DNNominal diameter in mm20, 50, 100, 200
Inv_USD2015permInstall cost in USD2015 per metre of pipe491.53

Other columns (D_ext_m, D_int_m, D_ins_m, Vdot_min_m3s, Vdot_max_m3s, code) are used by Part 2’s hydraulic simulation. If your scenario inherits the default CH/DE/SG databases from CEA, all columns are already present.

If the required diameter produced by the simulation exceeds the largest DN in the database, the tool errors out rather than silently snapping to the largest available size — add a larger pipe row to the database, or check why the simulation is producing an oversized diameter.

Understanding Results

Key Performance Indicators

Heat Losses:

  • Well-designed DH: 10-20% annual losses
  • Older DH networks: 20-35% losses
  • Low-temperature DH: 5-15% losses

Pumping Energy:

  • Typical: 1-3% of delivered heat energy
  • Long networks or high ΔT: Up to 5%
  • Affects system efficiency significantly

Pipe Sizes:

  • Small buildings: DN25-DN50 (25-50 mm diameter)
  • Medium buildings: DN50-DN100
  • Main distribution: DN100-DN300
  • Large district mains: DN300-DN600

Validation Checks

  1. Pressure feasibility: All pressures should be positive (no cavitation)
  2. Temperature feasibility: Return temp > supply temp at all points should never occur
  3. Reasonable losses: Total losses typically 10-20% for new networks
  4. Flow velocities: Typically 0.5-3 m/s (check derived from mass flow and diameter)

Advanced Options

Network Temperature Regimes

High-Temperature DH (80-90°C):

  • Traditional systems
  • Higher heat losses
  • Suitable for old buildings

Low-Temperature DH (50-70°C):

  • Modern systems
  • Lower heat losses
  • Requires better building insulation
  • Enables heat recovery sources

Very Low-Temperature DH (30-50°C):

  • Ultra-modern systems
  • Minimal heat losses
  • Requires heat pumps at buildings
  • Can also provide cooling

Pipe Insulation Standards

  • Standard: Typical for urban DH (λ ≈ 0.023 W/mK)
  • High performance: Better insulation for lower losses (λ ≈ 0.018 W/mK)
  • Twin pipes: Pre-insulated pipe pairs (supply + return)

Tips

  1. Temperature optimisation: Lower supply temperatures reduce heat losses
  2. Pressure management: Long networks may need intermediate pumping stations
  3. Insulation pays off: Better insulation reduces operating costs
  4. Validate with reality: Compare results with existing network data if available
  5. Consider future growth: Size pipes with expansion margin (10-20%)

Troubleshooting

Issue: Simulation fails or crashes

  • Solution: Check network layout for disconnected segments
  • Solution: Verify all buildings in network have valid demand data
  • Solution: Try disabling multiprocessing for debugging

Issue: Unrealistic pressure drops (very high or negative)

  • Solution: Check network connectivity and flow directions
  • Solution: Verify pipe properties in database
  • Solution: Review supply/return temperature settings

Issue: Very high heat losses (>30%)

  • Solution: Check pipe insulation settings
  • Solution: Verify ground temperature is reasonable
  • Solution: Consider lower supply temperatures

Issue: No pump requirements calculated

  • Solution: Check that network has defined plant location
  • Solution: Verify pressure boundary conditions

Thermal Network Part 2b: Multi-Phase Sizing

Overview

Optimises pipe sizing across a sequence of networks that represent a phased rollout (and/or phased decommissioning) of a thermal network over time. Instead of sizing each phase independently, Part 2b sees the full timeline at once and decides when each pipe should be installed, replaced, kept, or left idle — minimising total capital + replacement cost under a sunk infrastructure cost model.

When to Use

  • Planning incremental network rollouts (e.g. connect district A now, district B in 2050, district C in 2075)
  • Evaluating phased decommissioning (buildings drop off the network over time)
  • Choosing between “oversize now vs replace later” strategies
  • Comparing cost of different phasing plans

Physical Model: Sunk Infrastructure

Invariant: once a pipe is installed in any phase, it stays in the trench forever. No salvage value, no removal cost, no physical downsize. Connected buildings, however, can change freely between phases — additions AND removals are allowed.

Consequences:

  • Phase-N flow simulation uses only phase N’s connected set. Decommissioned buildings contribute zero demand to phase N.
  • A pipe whose downstream building was decommissioned is labelled idle in that phase: the pipe is preserved in the trench at its previously installed DN, but carries no flow and costs nothing that phase.
  • A pipe that is reactivated later (its consumer comes back) keeps the originally-installed DN if demand fits, or triggers a replace if demand grew.
  • Required DN can never exceed the largest DN in the cost database — the tool errors out rather than silently snapping.

Per-Phase Action Vocabulary

Every edge × phase pair is labelled with one of:

ActionMeaningCAPEX
nonePipe has not been installed yet in any prior phase0
installPipe is being installed for the first time this phasefull
replaceRequired DN > installed DN; pipe is being upgradedreplace × replacement-cost-multiplier
keepPipe exists, required DN ≤ installed DN, still flowing0
idlePipe installed in a prior phase, no flow this phase (decommissioned building)0

Prerequisites

  • Thermal Network Part 1 run for each phase (e.g. sub1, sub2, sub3). The typical workflow is:
    1. Run Part 1 for sub1 (the initial network)
    2. Run Part 1 for sub2 using existing-network=sub1 + adjusted heating-/cooling-connected-buildings
    3. Run Part 1 for sub3 using existing-network=sub2 + further adjustments
  • Pipe cost database (THERMAL_GRID.csv) with pipe_DN and Inv_USD2015perm columns (see Part 2 above)
  • Each phase’s consumer buildings must have energy demand calculated

Key Parameters

ParameterDescriptionTypical Value
phasing-plan-nameIdentifier for this phasing plane.g. plan8
network-name (list)Ordered list of per-phase networks from Part 1['sub1', 'sub2', 'sub3']
phase-completion-year (list)Calendar years for each phase (same length as network-name)['2025', '2050', '2075']
network-typeDH or DC (multi-phase runs one service at a time)['DH']
sizing-strategyHow to trade off install vs replacement costoptimise
replacement-cost-multiplierCost penalty for replacing a pipe in a later phase1.5

Sizing Strategies

StrategyBehaviour
optimiseFor each pipe, compare “size for each phase and replace as demand grows” vs “pre-size at final-phase DN” and pick the cheaper option
size-per-phaseAlways size each pipe for the current phase’s demand; replace when demand grows
pre-size-allInstall every pipe at its final-phase DN up front (never replaces)

How to Use

  1. Run Part 1 for each phase in chronological order, using existing-network to chain them:

    Part 1 run 1: network-name = sub1, existing-network = (blank), heating-connected-buildings = [initial set]
    Part 1 run 2: network-name = sub2, existing-network = sub1, heating-connected-buildings = [phase-2 set], network-layout-mode = filter (or augment)
    Part 1 run 3: network-name = sub3, existing-network = sub2, heating-connected-buildings = [phase-3 set], network-layout-mode = filter

    Buildings can be added OR removed between phases — the filter mode handles both.

  2. Run Part 2 for each phase individually (thermal-network tool) to generate per-phase simulation results. This populates the edge_list.csv metadata that Part 2b reads to get per-pipe flow requirements.

  3. Run Part 2b:

    • Navigate to Thermal Network Design → Part 2b: Multi-Phase
    • Set phasing-plan-name (e.g. plan8)
    • Set network-name to your ordered phase list: ['sub1', 'sub2', 'sub3']
    • Set phase-completion-year to matching years: ['2025', '2050', '2075']
    • Pick sizing-strategy and replacement-cost-multiplier
    • Click Run

Output Files

All Part 2b outputs go under outputs/data/thermal-network/phasing-plans/{phasing-plan-name}/{DH|DC}/:

  • phasing_summary.csv — one row per phase: year, connected-building count, peak demand, install + replacement cost, plus a new num_idle column counting decommissioned-but-preserved pipes
  • pipe_sizing_decisions.csv — one row per (edge, phase) with action (install / replace / keep / idle / none), DN, cost
  • edges_timeline.csv — timeline of every installed pipe with its per-phase DN and action. Idle phases are emitted with their installed DN preserved so you can trace the full life of a pipe
  • nodes_timeline.csv — one row per unique node with phase_introduced and phase_last_seen (the latter tells you when a consumer was decommissioned)
  • layout/edges.shp + layout/nodes.shptimeline shapefile covering the union of every pipe ever installed, with attributes: ph_intro, yr_intro (first install), ph_last, yr_last (last active phase), idle_final (1 if the pipe is idle in the final phase), DN_final, num_repl, cost_USD
  • Per-phase subfolders (sub1/layout/, sub2/layout/, sub3/layout/) — each contains the full network layout visible at that phase, with every pipe labelled by its action for that phase

Note on ESRI shapefile column widths: attribute names are truncated to 10 characters, so the shapefile uses short names (ph_intro, yr_intro, ph_last, yr_last, idle_final, num_repl, cost_USD) rather than the longer names in the CSVs.

Understanding Multi-Phase Results

Reading the sizing decisions:

  • A pipe with phase 1 = install, phase 2 = keep, phase 3 = keep → installed once, cost only in phase 1, no upgrades needed
  • Phase 1 = install, phase 2 = replace, phase 3 = keep → installed small, upgraded in phase 2 at 1.5× cost
  • Phase 1 = install, phase 2 = idle, phase 3 = idle → installed in phase 1, building decommissioned in phase 2, pipe still in trench but carrying no flow
  • Phase 1 = none, phase 2 = install, phase 3 = keep → new pipe added in phase 2 (served a building added in phase 2)

Expected patterns:

  • Total CAPEX is heavily front-loaded if using pre-size-all or if all buildings connect in phase 1
  • num_idle grows over time if you’re modelling decommissioning
  • With optimise strategy, you should see a mix of install and replace actions depending on each pipe’s growth profile

Troubleshooting

Error: Phase N (subX) has consumer nodes that are not connected to any plant: ...

  • A phase dropped a trunk-middle building and left a downstream branch orphaned from the plant
  • Fix: re-run Part 1 for that phase with the trunk building kept, or adjust the layout so the surviving consumers still have a path to a plant

Error: THERMAL_GRID.csv is missing required column(s): ['Inv_USD2015perm']

  • Your pipe cost database is missing the canonical column
  • Fix: use the default CH/DE/SG database, or add a column named Inv_USD2015perm (per-metre install cost in USD2015)

Error: Pipe sizing needs DN N mm, but the largest DN in the cost database is M mm

  • The simulation produced a required diameter larger than anything in the database
  • Fix: add a larger pipe row to THERMAL_GRID.csv, or check why the simulation is producing an oversized diameter

Error: Thermal-network simulation failed for phase N (subX): ...

  • One of the per-phase single-phase simulations crashed
  • Fix: run thermal-network directly on that phase to get the raw error, then troubleshoot normally (missing demand files, disconnected graph, etc.)

Complete Thermal Network Workflow

Standard Single-Network Workflow

  1. Data Preparation:

  2. Network Layout (Part 1):

    • Give your network a name (e.g. baseline)
    • Select service(s): DH, DC, or both
    • Leave existing-network blank for fresh auto-generation
    • Review the generated layout.shp and per-service node files
  3. Network Sizing (Part 2):

    • Select the network name created in Part 1
    • Set supply/return temperatures appropriate for the service
    • Review pipe sizes, heat losses, pumping energy
  4. Optimisation (optional):

  5. Analysis (via what-if scenarios):

Phased / Multi-Phase Workflow

Use this when you want to model a network that evolves over time — e.g. connect the city centre in 2025, expand to the northern district in 2050, decommission the steel mill in 2075.

  1. Data preparation: same as single-network (demand + streets).

  2. Phase 1 layout:

    • Run Part 1 with network-name = sub1, existing-network = (blank), connected buildings = initial set.
  3. Phase 2 layout:

    • Run Part 1 with network-name = sub2, existing-network = sub1, network-layout-mode = filter (or augment), connected buildings = phase-2 set.
    • Buildings can be added OR removed relative to phase 1.
  4. Phase 3 layout (and so on):

    • Run Part 1 with network-name = sub3, existing-network = sub2, same pattern.
  5. Per-phase flow & sizing (Part 2):

    • Run Part 2 for each of sub1, sub2, sub3 individually. This gives per-phase demand, mass flow, and an edge list that Part 2b will consume.
  6. Multi-phase optimisation (Part 2b):

    • Run Part 2b with phasing-plan-name = plan8, network-name = ['sub1','sub2','sub3'], phase-completion-year = ['2025','2050','2075'], sizing-strategy = optimise.
    • Review phasing_summary.csv, pipe_sizing_decisions.csv, and the timeline shapefile in the map viewer.

District Cooling Workflow

Same structure as district heating, but:

  • Choose DC (district cooling) in Part 1
  • Set cooling temperatures in Part 2 (e.g. 6°C / 12°C)
  • Use cooling demands from the demand calculation

Network Design Best Practices

Layout Design

  • Follow streets: Easier permitting and construction
  • Minimize length: Reduce capital cost and heat losses
  • Strategic branching: Balance tree simplicity with reliability
  • Future-proof: Consider expansion areas

Operating Strategy

  • Temperature optimisation: Lower temps = lower losses
  • Load management: Balance peak loads across network
  • Seasonal adjustment: Vary temperatures with season
  • Smart controls: Use real-time monitoring and control

Pipe Sizing Principles

  • Design for peak load: Ensure adequate capacity for coldest day
  • Consider velocity limits: 0.5-3 m/s typical range
  • Pressure constraints: Maximum ~16 bar in most systems
  • Standard sizes: Use common pipe diameters for cost efficiency


Further Reading

  • District heating design handbook
  • EN 13941: Design and installation of pre-insulated bonded pipe systems
  • IEA DHC Annex documents
  • 4th Generation District Heating (4GDH) concepts